Thanks to its characteristics, the Passivhaus is able, in the summer, to protect  against overheating and, in the winter,  use the most of the contributions from solar energy  as well as the  heating gains  produced in the building by the presence of people and their activities. This ensures a high comfort in winter and summer, with a very reduced  supply of energy  by mechanical plant.



Passivhaus ensures to its inhabitants a high level of comfort and reduced energy consumption, thanks to a series of  technical measures, as identified by a detailed design,  carried out  at  fieldyard  via  a precise and meticulous care of construcion details.



It is precisely for the remarkable reduction of the “active” role of the air-conditioning systems in summer and in winter that was born the concept of “passive house”, now a standard design and construction well proven and widespread. The shared knowledge is available to technicians, who can learn techniques and design processes independently or through training courses, and to  citizens, who can take advantage of the knowledge of the professionals to built an house in which to live well and save energy in  respect of the environment.



1) insulation   adequate and of high quality;

2) windows and doors high performance;

3) absence of  thermal  bridge ;

4) air tighness  of envelope ;

5) mechanical  ventilation with  heat recovery .



As you reach this result? Through a well thought-out design and a careful construction in the yard that  matches  the five fundamental points of a Passivhaus:




The


TECHNICAL CHOISE

must match  the following:

5puntifondamentipassivhaus500x560

1) level the air tightness of the building measured with the blower door test    n50 below 0,6 1/h;

2) annual net energy for heating and cooling  below 15 kWh/sqm;

3) heating load and cooling  less than 10 W/sqm;

4) annual requirement of the total primary energy for domestic hot water, heating, cooling, ventilation and electrical uses less than 120 kWh/sqm.

5puntifondamentipassivhaus500x560

The buildings that comply with the principles and values listed above, may be certified by the Passivhaus Institut, through the involvement of a  Passivhaus certifier, which checks the project,  the energy audits of the  constructive detail,  the energy calculation is carried out with the PHPP sheets, the construction in the yard, and the required test at the end of the work.